Warning lights are described in EN 50191 in connection with high voltages. This standard (unfortunately only valid in Europe) requires warning lights to be present in workplaces with voltages of 1,000 V and above. These red and green lights indicate the status of high voltage generation in the test panel. If the red light is active, high voltage can generally be generated. However, this does not necessarily mean that high voltage is present. If the green light is active, this confirms that there is definitely no high voltage present and being generated. The warning light is solely for the protection of the test personnel and must not be confused with the test result "Good" or "Fault".

Suitable for

Hipot tester HA 3600D
  • Plug-in 14" / 3 HU
  • High voltage test AC: 0 - 5,000 V / 0 - 100 mA
  • Burning: Troubleshooting with 150 mA

$3,290.79
Hipot tester HA 1885B
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ 
  • ARC detection (optional): 0 - 100 %
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$4,185.68
Hipot tester HA 1885G

  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA
  • ARC detection (optional): 0 - 100 %
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$6,016.28
Hipot tester HA 1885J
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 100 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • ARC detection (optional): 0 - 100 %
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$6,696.89
Hipot safety analyser KT 1880B
  • Plug-in 19'' / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 10 - 30 A / 0 - 400 mΩ
  • Equivalent leakage current test AC: 100 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Function test / current consumption AC: 4 A (option: 1 A, 10 A or 16 A)
  • Wide-range power supply unit: 90 to 253 V / 50 Hz / 60 Hz

$5,318.32
Hipot safety analyser KT 1886B
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω 
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 0 - 1,000 Ω
  • Function test AC/DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4,000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz

$7,545.86
Hipot safety analyser KT 1886J
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 50 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω 
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 0 - 1.000 Ω
  • Function test AC/DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4,000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz

$8,450.95