The most important procedure in all safety tests is the high-voltage test. This test is very often carried out manually, with the safety test probe forming the link between the person, the high-voltage test device and the DUT. It is intended to safely contact the high voltage, but also to protect the person from life-threatening contact with the high voltage.

The SP 02 and SP 03 safety test probes fully meet these requirements. In addition, great importance was attached to the ergonomics and handling of the probes. Especially when testing hundreds of times a day, this point plays a decisive role in test comfort and therefore also test safety. The high-voltage test probes from SPS electronic are available with or without a start switch and with different cable lengths.

Suitable for

Hipot tester HA 3600D
  • Plug-in 14" / 3 HU
  • High voltage test AC: 0 - 5,000 V / 0 - 100 mA
  • Burning: Troubleshooting with 150 mA

$3,578.46
Hipot tester HA 1800M
  • Plug-in 14" / 3 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$3,527.42
Hipot tester HA 1805B
  • Ergonomic desktop device
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • ARC detection (optional): 0 - 100 %
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$5,150.76
Hipot tester HA 1885B
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ 
  • ARC detection (optional): 0 - 100 %
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$4,551.58
Hipot tester HA 1885G

  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA
  • ARC detection (optional): 0 - 100 %
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$6,542.20
Hipot tester HA 1885J
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 100 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • ARC detection (optional): 0 - 100 %
  • Wide-range power supply unit: 90 V to 253 V, 50 Hz / 60 Hz

$7,282.30
Hipot safety analyser KT 1880B
  • Plug-in 19'' / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 10 - 30 A / 0 - 400 mΩ
  • Equivalent leakage current test AC: 100 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Function test / current consumption AC: 4 A (option: 1 A, 10 A or 16 A)
  • Wide-range power supply unit: 90 to 253 V / 50 Hz / 60 Hz

$5,783.24
Hipot safety analyser KT 1885K
  • Plug-in 19'' / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz
  • Only for 19" system installation

$5,411.52
Hipot safety analyser KT 1886B
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω 
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 0 - 1,000 Ω
  • Function test AC/DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4,000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz

$8,205.49
Hipot safety analyser KT 1886J
  • Plug-in 19" / 5 HU
  • High voltage test AC: 100 - 5,500 V / 0 - 100 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 50 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω 
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 0 - 1.000 Ω
  • Function test AC/DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4,000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz

$9,189.71
Hipot safety analyser LG 1800B
  • Ergonomic desktop device
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ 
  • Ground bond test AC: 10 - 30 A / 0 - 400 mΩ 
  • Equivalent leakage current test AC: 100 - 270 V / 0 - 10 mA 
  • Continuity test DC: 24 V / 0 - 600 mA
  • Function test / current consumption AC: 4 A (option: 1 A, 10 A or 16 A) 
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz

$4,949.93
Hipot safety analyser LG 1805B
  • Ergonomic desktop device
  • High voltage test AC: 100 - 5,500 V / 0 - 3 mA
  • High voltage test DC: 100 - 6,000 V / 0 - 10 mA
  • Insulation measurement DC: 100 - 6,000 V / 250 kΩ - 1 GΩ
  • Ground bond test AC: 1 - 30 A / 0 - 10 Ω
  • ARC detection (optional): 0 - 100 %
  • Equivalent leakage current test AC: 50 - 270 V / 0 - 10 mA
  • Continuity test DC: 24 V / 0 - 600 mA
  • Short-circuit test DC: 24 V / > 600 mA
  • Resistance measurement (optional): 1 - 1.000 Ω
  • Function test AC / DC: 0 - 300 V / 0 - 16 A
  • Active power measurement (optional): 0 - 4.000 W
  • Wide-range power supply unit: 90 to 253 V, 50 Hz / 60 Hz

$7,023.77